China’s Conference on Structural Experimentation and Testing Technology in Civil Engineering  is a major gathering for the latest in structural testing and seismic mitigation technology. The 8th conference, SECE 2024, held in Guangzhou from December 6th to 8th, 2024, at the Baiyun International Convention Center, was a collaborative effort between Guangzhou University Earthquake Engineering Research and Test Center (EERTC) and esteemed universities and technical societies, attracting over 400 leading experts and scholars in the field of civil engineering from around the globe.

SECE 2024 opening ceremony
Prof. Fulin Zhou, former ASSISi President and Honorary Director of SECE 2024, giving opening remarks at the conference

SECE 2024 highlighted the cutting-edge advancements in structural testing and seismic isolation, with a spotlight on structural testing and inspection, the synergy between physical and virtual experimental teaching, and the strategic planning and construction of laboratories.

Academic Reporting and Discussion

A highlight of SECE 2024 was the technical tour of EERTC, Guangzhou University, which offered attendees an in-depth look at the state-of-the-art laboratory facilities and science education base. The tour showcased demonstrations, such as a multi-point seismic simulation on a 54-meter tunnel model using advanced shaking tables, and a trial of isolation bearing tests capable of withstanding up to 10,000 tons.

EERTC Laboratory Building
EERTC 8 m x 10 m and Dual 4 m x 4 m Multi-Table Seismic Simulation Testing System
Performance Specifications
8 m x 10 m Shaking Table System4 m x 4 m Shaking Table System
Frequency range: 0.1~30 HzFrequency range: 0.1~50 Hz
Maximum horizontal displacement: ±0.80 m
Maximum vertical displacement: ±0.40 m
Maximum horizontal displacement: ±0.30 m
Maximum vertical displacement: ±0.15 m
Maximum horizontal velocity: ±1.20 m/s
Maximum vertical velocity: ±0.83 m/s
Maximum horizontal velocity: ±1.50 m/s
Maximum vertical velocity: ±1.30 m/s
Maximum horizontal acceleration: ±1.6 g
Maximum vertical acceleration: ±1.0 g
Maximum horizontal acceleration: ±1.5 g
Maximum vertical acceleration: ±1.0 g
EERTC 10,000-Ton Isolation and Energy Dissipation Device Testing System
Performance Specifications
10,000-Ton Isolation and Energy Dissipation Device Testing System
Maximum vertical compression load and velocity: 100,000 kN, 254 mm/s
Maximum horizontal load: 10,000 kN
Maximum vertical tension load: 30,000 kN
Maximum horizontal velocity: 1,000 mm/s (longitudinal) and 800 mm/s (lateral)
Maximum horizontal displacement: ±1.50 m (longitudinal) and ±0.60 m (lateral)
EERTC Laboratory Exhibition Hall Tour
Multi-Linked Shake Table Demonstration Experiment
10,000-Ton Multi-Dimensional Isolation Device Demonstration Test for Compression, Tension, and Bi-axial Shear